How it works

HOW IT WORKS

Reagent alternative for the Beckman Coulter Vi-Cell

The Vi-Cell system by Beckman Coulter is an imaging system. designed for the analysis of yeast and mammalian cells suspended in culture media. The system automates the traditional and well-accepted trypan blue. dye exclusion method for cell counting and determination of cell viability. By reporting the percentage of viable cells in the culture.

Many industries

measure cell viability or the health of cells and culture systems grown in bioreactors. This information is then used to make modifications. to the cell culture environment and optimize the culture to ensure cell growth.

The traditional trypan blue dye exclusion method functions in a way that. when a cell dies the cell membrane becomes permeable renekton. which allows the dye to be absorbed into the cell. Live cell walls are not permeable to the trypan blue dye.

Reagent cells

Under a microscope, using the manual method. Beckman Coulter Vi-Cell. Reagent cells are seen to be darker in color due to the trypan blue dye being absorbed. Live cells under a microscope seem bright.

Beckman Coulter Vi-Cell system

The Beckman Coulter Vi-Cell system. automates this traditional method using a camera to take images. as cells are passed by the measurement zone.

software

The software then determines the percentage of viable cells. by using imaging contrast between the live, bright, cells and the non-viable, dark, cells. The reagent system resides inside the Vi-Cell and is designed. for the user to install and replace as needed.

Vi-Cell system

The Vi-Cell system uses four reagent lines to connect to the reagent pack. These lines are all color-coded to allow for easy and proper installation. Please note the improper installation of the reagent lines. to the reagent pack will result in erroneous data.

Cell Viability Reagent Kit

The Cell Viability Reagent Kit from Cell Viability Incorporated. is a direct replacement for the reagent system. for the Vi-Cell system from Beckman Coulter.

The performance of these packages has been proven to be equivalent. quality and performance at significant savings in price. The system consists of bottles that are clearly color coded.

After installing the Cell Viability Reagent Pack follow the instructions as listed. in the Beckman Coulter Vi-Cell. instrument manual including the “Instrument” and “Replace Reagent Pack” from the instrument software toolbar.

This will prime the Vi-Cell system with the new reagent pack and reset the reagent level meter. Manual verification is recommended which is done. by checking the five LED lights in the reagent compartment. To ensure they are all illuminated Beckman Coulter Vi-Cell Reagents.

Please note that if any of these LED indicators are not illuminated. select the “Prime” function in the “Instrument” toolbar.

The LED indicators point out the lines. Connected to the Cell Viability reagent pack are primed or not.